Catalog item

PUMP,FUEL,METERING AND DISTRIBUT

2915FSC
01NCB code
703-3580Item number
NIIN 01-703-3580
Request a quote
DEMIL code
Q

Identification

Item name code
60879
PINC
0060879
Criticality code
X
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
31-AUG-22
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
A
Schedule B export code
8803300060

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
28-20-17 REV 173760
ITT AEROSPACE CONTROLS LLC DBA ITT AEROSPACE CONTROLS UNIT S
AD9D9Z4A
844073760
ITT AEROSPACE CONTROLS LLC DBA ITT AEROSPACE CONTROLS UNIT S
A32D9Z4A

Characteristics

DISCHARGE FLOW RATEGALLONS PER MINUTE 2.5
OVERALL LENGTHMILLIMETERS MAXIMUM 209.94
OVERALL HEIGHTMILLIMETERS NOMINAL 87.63
OVERALL WIDTHMILLIMETERS NOMINAL 82.55
MOUNTING HOLE DIAMETERMILLIMETERS NOMINAL 5.64
MOUNTING HOLE QUANTITY4
MOUNTING METHODBOLTED
OPERATING TEMP RANGECELSIUS -55.0 TO 70.0
MATERIAL BURSTING STRENGTHPOUNDS PER SQUARE INCH GAUGE (PSIG) 360.0
END ITEM IDENTIFICATIONKC-390
USAGE DESIGNVEHICULAR
USAGE DESIGNFUEL SYSTEM PURGE PUMP FOR KC-390
OPERATING VOLTAGE IN VOLTS120.5
CURRENT RATINGAMPERES 2.5
PRESSURE RATINGPOUNDS PER SQUARE INCH (PSI) 240.0
WORKING PRESSURE RATINGPOUNDS PER SQUARE INCH (PSI) MAXIMUM 120.0
VOLTAGE IN VOLTS AND CURRENT TYPEAC 101.5 AND AC 120.5
UNPACKAGED UNIT WEIGHTKILOGRAMS MAXIMUM 1.996
PART NAME ASSIGNED BY CONTROLLING AGENCYFUEL PURGE PUMP
SPECIAL FEATURESMATERIAL: ALUMINUM. OPERATING VOLTAGE:101.5 TO 120.5 VAC (390 TO 410 HZ). EMERGENCY VOLTAGE: 101.5 TO 120.5 VAC (360 TO 440 HZ). IN-RUSH: 3.75 AMPERES MAXIMUM FOR 45 SECONDS AT -45 C. PRESSURE - OPERATING: 0 TO 120 PSIG. PROOF: 240 PSIG. BURST: 360 PSIG. ELECTRICAL CONNECTOR: MS3102E16S-4P. FLOW RATE: 2.5 GPM MINIMUM BETWEEN 5 TO 6 PSIG (136 TO 143 KPA) DISCHARGE PRESSURE. FUEL: JET A, JET A-1, JP-4, JP-8, TS-1, RT, NO 3 JET FUEL, AND ALTERNATIVE AND SYNTHETIC FUELS.
FUNCTIONAL DESCRIPTIONCOMPONENT OF THE FUEL SYSTEM. THE PUMP ASSEMBLY IS AN AC MOTOR DRIVEN PUMP THAT PURGES FUEL LINES BEFORE AND AFTER AIRCRAFT FLIGHT. THE PUMP HOUSING INCORPORATES THE REQUIRED ELECTRICAL AND FLUID FITTINGS. PROVIDES PRESSURE TO TRANSFER ACCUMULATED FUEL INTO THE PRESSURE REFUELING LINE TO THE WING TANK AFTER THE PRESSURE REFUELING OPERATION. THIS PUMP IS IMPLEMENTED IN THE PRIMARY AND AUXILIARY TANKS OF THE FUEL SYSTEM ON THE KC-390 AIRCRAFT.
MATERIALALUMINUM
MEDIA FOR WHICH DESIGNEDJP-8 JET FUEL AND JP-4 JET FUEL
PROPRIETARY CHARACTERISTICSPACS
SHAPEIRREGULAR

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
WZ01WZ01-DEC-25WZ81WZ
YA01YA01-APR-23YA81YA
ZP01ZP01-AUG-22ZP81ZP

Freight

ACTY CD
ZP

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
31-AUG-2022
NIIN status code
0

Request a quote