Catalog item

DEHYDRATOR UNIT,NONREACTIVATING

4440FSC
01NCB code
470-3818Item number
NIIN 01-470-3818
Request a quote
DEMIL code
A

Identification

Item name code
20530
PINC
0020530
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
16-DEC-99
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
A

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
174790F960
ETI INC DBA ETI INC
A5949Z4B
ADH3-COM-174790F960
ETI INC DBA ETI INC
A3949Z4A

Characteristics

END ITEM IDENTIFICATIONSATCOM
UNIT PACKAGE QUANTITY1
USAGE DESIGNWAVEGUIDE AND COAX
CONTAINER TYPECARTON
BODY OVERALL HEIGHTINCHES NOMINAL 6.220
BODY OVERALL LENGTHINCHES NOMINAL 19.000
BODY OVERALL WIDTHINCHES NOMINAL 19.000
CUBIC MEASURECUBIC INCHES 1895.250
UNPACKAGED UNIT WEIGHTPOUNDS MAXIMUM 31.300
SPECIAL FEATURESAUTOMATIC REGENERATION; DIRECT DIGITAL (RS-422/RS-485) CONTROL; LED DISPLAY FOR OPERATING AND ALARM DATA; 120/230 VOLT, 50/60 HZ OPERATION STANDARD; ENGLISH OR SI CALIBRATION STANDARD; S-A AND TERMINAL COMMUNICATION PROTOCOLS; DUAL AIR PUMPS; CE CERTIFICATION; U-L 1950/IEC 950; EXCEPTIONALLY LOW NOISE AND VIBRATION LEVELS; USES ALUMINUM OXIDE DESICCANT; INTERNAL EVAPORATOR ELIMINATING THE NEED FOR A WATER DRAIN; CONSUMES A MAXIMUM OF 150 VA DURING REGENERATING AND 60 VA OTHERWISE; 0.5 PSIG OUT; RACK MOUNTED (19 INCH)
SUPPLEMENTARY FEATURESPRESSURE: 0.25 TO 0.5 PSIG; FLOW: 26 FT3/HR; MAX DEW POINT: -40 DEG F; RELAY CONTACT RATING: 1 AMP AT 240 VAC; OPERATION TEMP: -40 TO 150 DEG F; CABINET DIMENSION: 5.25 - H, 19.0 - W, 19.0 INCHES - L

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YA01YA01-MAY-12YA81YA
ZD01ZD01-OCT-08ZD81ZD