Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
085-1947Item number
NIIN 00-085-1947
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-61
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
- Last known source of supply
- S9E
Part numbers
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| TERMINAL LENGTH | INCHES NOMINAL 1.500 |
| OVERALL HEIGHT | INCHES NOMINAL 1.531 |
| BODY LENGTH | INCHES NOMINAL 0.402 |
| BODY WIDTH | INCHES NOMINAL 0.148 |
| BODY HEIGHT | INCHES NOMINAL 0.370 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.200 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 300.0 |
| THERMAL TIME CONSTANT IN SECONDS | 20.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 3.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 200.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 250.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -30.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 300.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -10.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 104.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 520.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 24.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 48.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 96.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 232.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 680.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 16.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 34.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 |
| INCLOSURE TYPE | ENCASED |
| ZERO POWER RESISTANCE | KILOHMS 8.000 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
MOE rules
- MOE rule
- ZH01
- MOE CD
- ZH
- Date assigned
- 01-APR-91
- PICA
- ZH
- PICA LOA
- 81
- Auth collab
- ZH
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 21-MAR-1968
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5905
- Cancelled NIIN
- 5905-00-770-5239
- NIIN status code
- 7
- Effective date
- 02-JUL-2026
- DEMIL code
- A
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.