Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
175-5447Item number
NIIN 00-175-5447
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
- Last known source of supply
- S9E
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| 19MS715-2 | 1MY97 AGILENT TECHNOLOGIES, INC. DIV AGILENT TECHNOLOGIES HEADQUARTERS | A | 3 | 2 | 5 | ZZ | ||
| RTD4 | 21900 FEDERAL DIV OF VICTOREEN INSTRUMENT CO INC | H | 5 | 9 | X | XX | 3 | B |
| 19MS715-2 | 28480 HEWLETT-PACKARD COMPANY DBA HP | A | 5 | 9 | X | XX | 3 | B |
| 227898 | 56232 LOCKHEED MARTIN CORPORATION DIV RMS - MITCHEL FIELD | A | 5 | 9 | X | XX | 3 | B |
| D168392 | 64959 AMERICAN TELEPHONE AND TELEGRAPH CO | R | 5 | 9 | X | XX | 3 | B |
| D168392 | 70408 AT AND T CORP | H | 5 | 9 | 5 | 9Z | 3 | B |
| P320A60 | 73760 ITT AEROSPACE CONTROLS LLC DBA ITT AEROSPACE CONTROLS UNIT S | A | 3 | 2 | X | XX | 3 | D |
| B851648 | 98738 HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS | A | 3 | 2 | X | XX | 3 | D |
Characteristics
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES NOMINAL 1.0624 |
|---|---|
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| OVERALL LENGTH | INCHES NOMINAL 1.250 |
| TERMINAL LENGTH | INCHES MINIMUM 3.750 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -11.0 TO 11.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.1 TO 12.1 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.4 TO 8.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.6 TO 8.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.9 TO 8.9 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | INCHES NOMINAL 1.000 |
| INCLOSURE TYPE | ENCAPSULATED |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | INCHES NOMINAL 0.6874 |
| OVERALL HEIGHT | INCHES NOMINAL 0.313 |
| OVERALL WIDTH | INCHES NOMINAL 0.875 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.025 |
| UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.1285 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 150.0 |
| THERMAL TIME CONSTANT IN SECONDS | 80.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 150.0 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 4.40 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 25.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -30.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| CUBIC MEASURE | CUBIC INCHES 0.342 |
| ZERO POWER RESISTANCE | OHMS 725.000 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 1 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 25.375 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 13.05 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 116.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 239.25 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 13.05 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 3.045 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT OHMS 725.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 46.4 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.465 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 58.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -10.0 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| YA01 | YA | 01-DEC-99 | YA | 81 | YA |
| YB01 | YB | 01-APR-91 | YB | 81 | YB |
| ZF01 | ZF | 01-FEB-97 | ZF | 81 | ZF |
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH |
| ZR01 | ZR | 01-JUL-97 | ZR | 81 | ZR |
| ZW01 | ZW | 01-NOV-05 | ZW | 81 | ZW |
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Less than carload
- P
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 3
- Orig stdzn dec
- TX
- Dt stdzn dec
- 20-DEC-1969
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.