Catalog item

RESISTOR,THERMAL

5905FSC
00NCB code
802-9668Item number
NIIN 00-802-9668
Request a quote
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8533400080
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
ES1411-220418
DRS SUSTAINMENT SYSTEMS, INC.
R125TX3D
R11124446
GENERAL ELECTRIC COMPANY
A595TX3B
1R11150157
THERM-O-DISC INC SUB OF EMERSON ELECTRIC CO
A52ETX3D
51RD190634
GULTON INDUSTRIES INC
Y32ETX3D
R11110627
SECO TOOLS, LLC DBA SECO
A395TX3D

Characteristics

POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS6.0
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
CUBIC MEASURECUBIC INCHES 0.012
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.0 TO 12.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.0 TO 14.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.0 TO 17.0
BODY OUTSIDE DIAMETERINCHES NOMINAL 0.110
TERMINAL DIAMETERINCHES NOMINAL 0.020
BODY LENGTHINCHES NOMINAL 1.625
STYLE DESIGNATOR
THERMAL TIME CONSTANT IN SECONDS95.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUSM4.40
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWEREIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 20.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERNINTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0
ZERO POWER RESISTANCEKILOHMS 100.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
REFERENCE TEMP IN DEG CELSIUS25.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT KILOHMS 6.8
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 12.5
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.0 TO 18.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 125.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT MEGOHMS 1.8
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT KILOHMS 327.4
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.5 TO 10.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPEIGHTH RESISTANCE-TEMPERATURE POINT KILOHMS 3.9
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 36.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT MEGOHMS 10.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 80.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTENTH RESISTANCE-TEMPERATURE POINT CELSIUS 200.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
SURFACE TREATMENTTERMINAL SOLDER
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 1.375
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -30.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-22.5 TO 22.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPNINTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.8
ZERO POWER RESISTANCE AT SPECIFIED TEMPTENTH RESISTANCE-TEMPERATURE POINT OHMS 660.0
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
MAXIMUM OPERATING TEMPCELSIUS 200.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.0 TO 20.0
INCLOSURE TYPEENCAPSULATED

MOE rules

MOE rule
ZU01
MOE CD
ZU
Date assigned
01-APR-91
PICA
ZU
PICA LOA
81
Auth collab
ZU

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-00-686-9289
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote