Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
802-9668Item number
NIIN 00-802-9668
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
- Last known source of supply
- S9E
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| ES1411-2 | 20418 DRS SUSTAINMENT SYSTEMS, INC. | R | 1 | 2 | 5 | TX | 3 | D |
| R111 | 24446 GENERAL ELECTRIC COMPANY | A | 5 | 9 | 5 | TX | 3 | B |
| 1R111 | 50157 THERM-O-DISC INC SUB OF EMERSON ELECTRIC CO | A | 5 | 2 | E | TX | 3 | D |
| 51RD1 | 90634 GULTON INDUSTRIES INC | Y | 3 | 2 | E | TX | 3 | D |
| R111 | 10627 SECO TOOLS, LLC DBA SECO | A | 3 | 9 | 5 | TX | 3 | D |
Characteristics
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 6.0 |
|---|---|
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| CUBIC MEASURE | CUBIC INCHES 0.012 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0 TO 17.0 |
| BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.110 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.020 |
| BODY LENGTH | INCHES NOMINAL 1.625 |
| STYLE DESIGNATOR | |
| THERMAL TIME CONSTANT IN SECONDS | 95.0 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | M4.40 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 20.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| ZERO POWER RESISTANCE | KILOHMS 100.000 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT KILOHMS 6.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 12.5 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.0 TO 18.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 125.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT MEGOHMS 1.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 327.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.5 TO 10.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT KILOHMS 3.9 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 36.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT MEGOHMS 10.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 80.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 200.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | INCHES NOMINAL 1.375 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -30.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -22.5 TO 22.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 660.0 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 200.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 |
| INCLOSURE TYPE | ENCAPSULATED |
MOE rules
- MOE rule
- ZU01
- MOE CD
- ZU
- Date assigned
- 01-APR-91
- PICA
- ZU
- PICA LOA
- 81
- Auth collab
- ZU
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 21-MAR-1968
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5905
- Cancelled NIIN
- 5905-00-686-9289
- NIIN status code
- 5
- Effective date
- 02-JUL-2026
- DEMIL code
- A
Request a quote