Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
804-2768Item number
NIIN 00-804-2768
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- U
- Hazardous material indicator
- N
- ESD/EMI code
- B
- Schedule B export code
- 8533400080
- Last known source of supply
- SMS
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 31TD2 | 50056 PIEZOTHERMX CORPORATION | A | 3 | 2 | E | TX | 1 | D | |
| 31TD2 | 90634 GULTON INDUSTRIES INC | Y | C | 1 | 6 | ZZ | AC | ||
| 8503775-2 | 02734 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN AEROSTRUCTURES DIV ADVANCED TECHNOLOGY LABORATORIES | A | 5 | 2 | 5 | TX | 3 | D | |
| 841008 | 06141 L3 AVIATION PRODUCTS, INC. DBA L3 TECHNOLOGIES | A | 5 | 9 | 5 | TX | |||
| 31TD2 | 09052 SAFT AMERICA INC. DBA TADIRAN BATTERIES DIV AVIATION DIVISION | A | C | 1 | 5 | ZZ | AC |
Characteristics
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.25 |
|---|---|
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 67.54 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 3.274 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 33.89 |
| BODY HEIGHT | INCHES MAXIMUM 0.160 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.013 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.9 TO 15.9 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.0 TO 16.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 100.0 |
| BODY LENGTH | INCHES MAXIMUM 0.100 |
| BODY WIDTH | INCHES MAXIMUM 0.160 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -30.0 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 174.7 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 805.3 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 18.43 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 17.92 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.4 TO 10.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.5 TO 13.5 |
| THERMAL TIME CONSTANT IN SECONDS | 5.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.6 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | M4.40 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 10.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -40.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 70.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 30.0 |
| ZERO POWER RESISTANCE | KILOHMS 1.000 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | INCHES MINIMUM 1.250 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.5 TO 17.5 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.9 TO 18.9 |
| INCLOSURE TYPE | ENCAPSULATED |
| CUBIC MEASURE | CUBIC INCHES 0.003 |
| MAXIMUM OPERATING TEMP | CELSIUS 105.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.2 TO 14.2 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.8 TO 14.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 34.28 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| ZR01 | ZR | 01-JUL-97 | ZR | 81 | ZR |
| ZT01 | ZT | 01-APR-91 | ZT | 81 | ZT |
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- 3
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 21-MAR-1968
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.