Catalog item
Request a quoteRESISTOR NETWORK,FIXED,FILM
5905FSC
01NCB code
109-2152Item number
NIIN 01-109-2152
- DEMIL code
- A
Identification
- Item name code
- 32068
- PINC
- 0032068
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 12-MAR-81
- Precious metals indicator
- A
- Hazardous material indicator
- N
- ESD/EMI code
- B
- Schedule B export code
- 8533100057
- Last known source of supply
- S9E
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 850-161-008 | 26055 PARKER-HANNIFIN CORPORATION DBA PNEUTRONICS DIV FLUID SYSTEMS DIVISION | A | 5 | 9 | 5 | TX | B | ||
| R50-0006-103 | 32997 BOURNS INC | A | 5 | 2 | 6 | ZC | 4 | D | |
| 4306R-101-103 | 32997 BOURNS INC | A | 3 | 2 | 3 | TX | 4 | D | |
| 235Z006U11 | 52599 DELTA DATA SYSTEMS CORP | H | 5 | 9 | 1 | TX | 4 | B | |
| 37002 | 56198 BIOTEK INSTRUMENTS, INC. DBA BIOTEK DIV BIO-TEK INSTRUMENTS LLC DBA BIOTEK INSTRUMENTS INC. | H | 5 | 9 | 5 | TX | B | ||
| 850-161-008 | 59211 PARKER-HANNIFIN CORPORATION DBA SERVICE AND SUPPORT OPERATION DIV SERVICES AND SUPPORT OPERATIONS | A | 5 | 2 | 5 | TX | |||
| 464-1571 | A486G NIMIKKEISTOKESKUS NCB FINLAND | A | 6 | 9 | 9 | WF | 4 | B | |
| 938625 | K0215 RACAL COMMUNICATIONS SYSTEMS LTD | R | 5 | 9 | 2 | ZK | 4 | D | |
| 41561-202-00-7 | K4556 BRITISH AEROSPACE DEFENCE SYSTEMS LTD T/A BAE SYSTEMS | R | 5 | 9 | 2 | ZK | 1 | B | |
| 41561-202-00-7 | KC1M9 BAE SYSTEMS MARITIME SERVICES LIMITED | A | C | 1 | 2 | ZZ | 1 | D | 9F |
| 938625 | K0162 THALES UK LIMITED SECURE COMMUNICATIONS AND INFORMATION SYSTEMS | A | 5 | 2 | 2 | ZK | B | ||
| 5255-251 | 05869 RAYTHEON COMPANY DIV RMD STRATEGIC | A | 5 | 2 | 5 | TU |
Characteristics
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -250.0 TO 250.0 |
|---|---|
| ELECTRICAL RESISTANCE | EACH RESISTOR KILOHMS 10.000 |
| RESISTANCE TOLERANCE IN PERCENT | -2.000 TO 2.000 |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
| INCLOSURE METHOD | ENCAPSULATED |
| TERMINAL QUANTITY | 6 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | INCHES MINIMUM 0.125 |
| BODY LENGTH | INCHES MAXIMUM 0.595 |
| BODY WIDTH | INCHES NOMINAL 0.080 |
| BODY HEIGHT | INCHES MAXIMUM 0.190 |
| SCHEMATIC DIAGRAM DESIGNATOR | |
| POWER DISSIPATION RATING IN WATTS | LOCATION NOT OTHERWISE SPECIFIED TOTAL NETWORK 0.750 |
| IDENTICAL VALUE RESISTOR QUANTITY | 5 |
| TERMINAL TYPE | PIN |
| STYLE DESIGNATOR |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| WF01 | WF | 01-FEB-12 | WF | 81 | WF |
| WG01 | WG | 01-OCT-17 | WG | 81 | WG |
| WB01 | WB | 01-FEB-05 | WB | 81 | WB |
| YD01 | YD | 01-NOV-16 | YD | 81 | YD |
| ZC01 | ZC | 01-APR-91 | ZC | 81 | ZC |
| ZE01 | ZE | 01-APR-91 | ZE | 81 | ZE |
| ZF01 | ZF | 01-APR-91 | ZF | 81 | ZF |
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH |
| ZG01 | ZG | 01-APR-91 | ZG | 81 | ZG |
| ZK01 | ZK | 01-APR-91 | ZK | 81 | ZK |
| ZN01 | ZN | 01-APR-91 | ZN | 81 | ZN |
| ZP01 | ZP | 01-MAY-98 | ZP | 81 | ZP |
| ZR01 | ZR | 01-DEC-07 | ZR | 81 | ZR |
| ZU01 | ZU | 01-MAY-08 | ZU | 81 | ZU |
| ZS01 | ZS | 01-APR-91 | ZS | 81 | ZS |
| ZT01 | ZT | 01-APR-91 | ZT | 81 | ZT |
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW |
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- 3
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 3
- Orig stdzn dec
- TX
- Dt stdzn dec
- 15-JUL-1992
- NIIN status code
- 0