Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
01NCB code
295-4532Item number
NIIN 01-295-4532
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 05-MAR-89
- Precious metals indicator
- A
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
- Last known source of supply
- S9E
Part numbers
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| OVERALL LENGTH | INCHES NOMINAL 3.222 |
| TERMINAL LENGTH | INCHES MINIMUM 0.231 AND INCHES MAXIMUM 0.241 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES NOMINAL 1.260 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | INCHES MINIMUM 2.260 AND INCHES MAXIMUM 2.300 |
| BODY LENGTH | INCHES NOMINAL 2.750 |
| BODY WIDTH | INCHES NOMINAL 0.865 |
| BODY HEIGHT | INCHES NOMINAL 1.730 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.630 |
| UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.157 |
| MAXIMUM POWER DISSIPATION RATING | WATTS 10.00 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 130.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 60.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS 10.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 140.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS 40.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 70.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -20.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT OHMS 14.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT OHMS 8.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 60.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT OHMS 9.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT OHMS 11.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 11.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT OHMS 9.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT KILOHMS 10.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 20.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -30.0 TO 30.0 |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | INCHES NOMINAL 2.280 |
| END ITEM IDENTIFICATION | RANSMITTERRF7 |
| INCLOSURE TYPE | ENCAPSULATED |
| ZERO POWER RESISTANCE | OHMS 10.000 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -30.0 TO 30.0 |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 2 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| ZE01 | ZE | 01-APR-91 | ZE | 81 | ZE |
| ZT01 | ZT | 01-APR-91 | ZT | 81 | ZT |
| ZW01 | ZW | 01-DEC-05 | ZW | 81 | ZW |
Freight
- ACTY CD
- TH
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 05-MAR-1989
- NIIN status code
- 0
Request a quote