Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
00NCB code
101-2239Item number
NIIN 00-101-2239
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
13-DEC-72
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290020
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
CMR06F472J0DL81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
CMR06F472G0DP81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
MILC39001-581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D

Characteristics

RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0013
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39001
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
BODY STYLE
RELIABILITY INDICATORESTABLISHED
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39001 TO 5
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0 TO 70.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -2.00 TO 2.00
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 4700.000
SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHM-MICROFARADS 33.0
TERMINAL DIAMETERINCHES NOMINAL 0.032
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.350
BODY HEIGHTINCHES MINIMUM 0.220 AND INCHES MAXIMUM 0.350
TERMINAL LENGTHINCHES MINIMUM 1.000
BODY LENGTHINCHES MINIMUM 0.610 AND INCHES MAXIMUM 0.700
BODY WIDTHINCHES MAXIMUM 0.580

MOE rules

MOE rule
ZW01
MOE CD
ZW
Date assigned
01-NOV-98
PICA
ZW
PICA LOA
81
Auth collab
ZW

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
04-NOV-1977
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.