Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
00NCB code
152-8283Item number
NIIN 00-152-8283
Request a quote
DEMIL code
A

Identification

Item name code
00008
PINC
0000008
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
18-OCT-71
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
M39006-03-137281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
MILC39006-381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D

Characteristics

TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -20.00 TO 20.00
CAPACITIVE ELECTRODE MATERIALTANTALUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 100.0
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
DC LEAKAGE AT MAXIMUM OPERATING TEMPMICROAMPERES 25.0
ELECTRICAL POLARIZATIONPOLARIZED
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 20.000
BODY LENGTHINCHES NOMINAL 2.203
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
ANODE TYPEPLAIN FOIL
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS112.0
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39006 TO 3
CASE INSULATION MATERIALPLASTIC
BODY STYLE
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-3
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
TERMINAL LENGTHINCHES NOMINAL 1.500
BODY DIAMETERINCHES MAXIMUM 0.406
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--ILC39006
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 3.000
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT10.0000

MOE rules

MOE rule
YJ01
MOE CD
YJ
Date assigned
01-APR-91
PICA
YJ
PICA LOA
81
Auth collab
YJ

Freight

ACTY CD
TX

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
18-FEB-1994
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.