Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
00NCB code
170-9862Item number
NIIN 00-170-9862
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
11-FEB-73
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290020
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MILC39001-581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D
CMR04F101G0DM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
CMR04F101J0DL81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B

Characteristics

RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
BODY STYLE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 10000.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 100.000
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39001
TERMINAL LENGTHINCHES MINIMUM 1.000
SCHEMATIC DIAGRAM DESIGNATOR
RELIABILITY INDICATORESTABLISHED
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -2.00 TO 2.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0008
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
BODY LENGTHINCHES MINIMUM 0.300 AND INCHES MAXIMUM 0.370
BODY WIDTHINCHES MAXIMUM 0.350
BODY HEIGHTINCHES MINIMUM 0.110 AND INCHES MAXIMUM 0.200
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.150
TERMINAL DIAMETERINCHES NOMINAL 0.016
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39001 TO 5
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0 TO 70.0
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YA01YA01-JAN-02YA81YA
YB01YB01-FEB-94YB81YB
YJ01YJ01-APR-91YJ81YJ
ZC01ZC01-APR-91ZC81ZC

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
05-FEB-1978
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.