Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
00NCB code
182-8400Item number
NIIN 00-182-8400
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
28-FEB-73
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290020
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
CMR04C150JPDM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
MILC39001-581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D

Characteristics

BODY LENGTHINCHES MINIMUM 0.300 AND INCHES MAXIMUM 0.360
TERMINAL DIAMETERINCHES NOMINAL 0.016
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
TERMINAL LENGTHINCHES MINIMUM 1.000
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0014
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39001
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -200.0 TO 200.0
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39001 TO 5
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 15.000
BODY STYLE
BODY HEIGHTINCHES MINIMUM 0.100 AND INCHES MAXIMUM 0.190
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.150
BODY WIDTHINCHES MAXIMUM 0.330
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 5000.0
SCHEMATIC DIAGRAM DESIGNATOR
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 150.0

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YD01YD01-AUG-16YD81YD
ZG01ZG01-APR-91ZG81ZG
ZR01ZR01-APR-91ZR81ZR

Freight

ACTY CD
TX

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
05-FEB-1978
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.