Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
00NCB code
192-2511Item number
NIIN 00-192-2511
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-MAR-73
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290020
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MILC39001-581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D
CMR05E470G0DP81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D

Characteristics

CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 47.000
TERMINAL LENGTHINCHES MINIMUM 1.000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -20.0 TO 100.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -2.00 TO 2.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0012
BODY HEIGHTINCHES MINIMUM 0.090 AND INCHES MAXIMUM 0.170
MATERIALCASE PLASTIC
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39001 TO 5
SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 10000.0
TERMINAL SURFACE TREATMENTSOLDER
BODY STYLE
BODY LENGTHINCHES MINIMUM 0.400 AND INCHES MAXIMUM 0.450
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39001
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.225
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
BODY WIDTHINCHES MAXIMUM 0.360
TERMINAL DIAMETERINCHES NOMINAL 0.025

MOE rules

MOE rule
ZW01
MOE CD
ZW
Date assigned
01-NOV-05
PICA
ZW
PICA LOA
81
Auth collab
ZW

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
10-MAR-1978
NIIN status code
0

Request a quote