Catalog item
Request a quoteCAPACITOR,FIXED,ELECTROLYTIC
5910FSC
00NCB code
197-0253Item number
NIIN 00-197-0253
- DEMIL code
- A
Identification
- Item name code
- 00008
- PINC
- 0000008
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 17-DEC-71
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- Schedule B export code
- 8532290040
- Last known source of supply
- S9E
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 1-444700-1 | 24856 ECTRON CORP | A | 5 | 2 | 4 | 9Z | D | ||
| TD3-035-475-20 | 24546 DALE ELECTRONICS INC A VISHAY INTERTECHOLOGY INC CO P O BOX 74 NORFOLK NE68702-0074 | H | C | 1 | 5 | 48 | 1 | B | |
| TDC475M035WSP | 50248 MALLORY ENGINEERING, INC. DBA DYNAMIC METALWORKS | A | C | 1 | 6 | TX | AW | ||
| 36601005 | 52297 DELTYME CORPORATION | H | C | 1 | 5 | 48 | 1 | B | |
| 804123-475 | 53938 EVANS & SUTHERLAND COMPUTER CORP | A | 5 | 2 | 5 | TX | |||
| 196D475X0020 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | 5 | 9 | 5 | SB | B | ||
| 196D475X9035JA1 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | 5 | 2 | E | TX | 3 | D | |
| 196D475X025KA1 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | C | 1 | 6 | TX | AW | ||
| 196D475X0025JA1 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | C | 1 | E | TX | 4X | ||
| 196D475X003SJA1 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | C | 1 | 5 | TX | AW | ||
| 196D475X0035JA1 | 86768 TELEDYNE INDUSTRIES INC TELEDYNE FLUID SYSTEMS REPUBLIC BUSINESS UNIT | H | C | 1 | 9 | TU | B | ||
| TDC475M035WSF | 90201 MALLORY SONALERT PRODUCTS, INC. | A | C | 1 | 6 | TX | AW | ||
| P2D-35-4.7T8 | 92731 LA MARCHE MFG CO. DBA LA MARCHE | A | 3 | 9 | A | TX | |||
| 859775-031 | 06141 L3 AVIATION PRODUCTS, INC. DBA L3 TECHNOLOGIES | A | C | 1 | 5 | 48 | AH | ||
| 58-577-002 | 08742 ASTEC AMERICA INC. | A | C | 1 | 5 | TX | AW | ||
| 184-9102-390 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | C | 1 | 5 | 48 | 1 | B |
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| ANODE TYPE | SOLID |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 35.0 |
| TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -10.00 TO 10.00 |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 6.000 |
| DC LEAKAGE AT REFERENCE TEMP | MICROAMPERES 2.000 |
| NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0 |
| MATERIAL | CASE PLASTIC |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
| BODY STYLE | |
| BODY LENGTH | INCHES MAXIMUM 0.225 |
| BODY WIDTH | INCHES MAXIMUM 0.425 |
| BODY HEIGHT | INCHES MAXIMUM 0.225 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 0.095 AND INCHES MAXIMUM 0.155 |
| ELECTRICAL POLARIZATION | POLARIZED |
| TERMINAL LENGTH | INCHES MINIMUM 0.625 AND INCHES MAXIMUM 0.875 |
| SCHEMATIC DIAGRAM DESIGNATOR | |
| TERMINAL SURFACE TREATMENT | SOLDER |
| CAPACITANCE VALUE PER SECTION | MICROFARADS SINGLE SECTION 4.700 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.020 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | Acquisition advice code | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|---|---|---|
| VK01 | VK | 01-NOV-24 | VK | 81 | VK | |||
| WB01 | WB | 01-FEB-05 | WB | 81 | WB | |||
| YA01 | YA | 01-DEC-99 | YA | 81 | YA | |||
| YB01 | YB | 01-APR-91 | YB | 81 | YB | |||
| YD01 | YD | 01-AUG-16 | YD | 81 | YD | |||
| YQ01 | YQ | 01-JAN-15 | YQ | 81 | YQ | |||
| YW01 | YW | 01-JUL-93 | YW | 81 | YW | |||
| ZC01 | ZC | 01-APR-91 | ZC | 81 | ZC | |||
| ZE01 | ZE | 01-APR-91 | ZE | 81 | ZE | |||
| ZF01 | ZF | 01-APR-91 | ZF | 81 | ZF | |||
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH | |||
| ZJ01 | ZJ | 01-APR-25 | ZJ | 81 | ZJ | |||
| ZP01 | ZP | 01-APR-91 | ZP | 81 | ZP | |||
| ZK01 | ZK | 01-NOV-95 | ZK | 81 | ZK | |||
| ZU01 | ZU | 01-JUL-05 | ZU | 81 | ZU | |||
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW | |||
| G860 | T1 | 0 | 0 | 01-APR-91 | C | 86 | 48 | 75 86 |
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- XXX
- Method of preservation
- A9
- Clng drying
- X
- Pres mat
- XX
- Wrap mat
- XX
- Cush dun
- XX
- THK
- X
- Unit cont
- XX
- PKG data source
- A
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- XX
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- 6Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0010
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 3
- Orig stdzn dec
- TX
- Dt stdzn dec
- 01-MAR-1994
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5910
- Cancelled NIIN
- 5910-01-013-4247
- NIIN status code
- 5
- Effective date
- 02-JUL-2026
- DEMIL code
- A
Request a quote