Catalog item

CAPACITOR,FIXED,CERAMIC DIELECTR

5910FSC
00NCB code
400-4534Item number
NIIN 00-400-4534
Request a quote
DEMIL code
A

Identification

Item name code
00007
PINC
0000007
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
07-MAR-69
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MILC11015-1981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D
CK06BX563K81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
G165-533-19688818
KEARFOTT CORPORATION DIV GUIDANCE AND NAVIGATION DIVISION
A595KE1B
BKB2738/49K1066
LEONARDO UK LTD
A522ZK1D
G165-533-1960D0D0
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
A515KE

Characteristics

NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -10.00 TO 10.00
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.185 AND INCHES MAXIMUM 0.215
BODY STYLE
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 100.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-11015-19
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.250
BODY LENGTHINCHES NOMINAL 0.290
BODY WIDTHINCHES NOMINAL 0.290
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHM-MICROFARADS 1000.0
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 56000.000
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGEWITH RATED VOLTAGE APPLIED SINGLE SECTION -25.0 TO 15.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.5000
BODY HEIGHTINCHES NOMINAL 0.090

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
WG01WG01-OCT-17WG81WG
YA01YA01-JAN-02YA81YA
YB01YB01-FEB-94YB81YB
YD01YD01-AUG-16YD81YD
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-APR-91ZG81ZG
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-JUL-05ZU81ZU
ZW01ZW01-NOV-98ZW81ZW

Freight

ACTY CD
TX

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
25-DEC-1972
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.