Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
00NCB code
436-1183Item number
NIIN 00-436-1183
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
09-JUL-74
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290020
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
CMR07F682J0DL81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
CMR07F682G0DM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
MILC39001-581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D
4112310-23005869
RAYTHEON COMPANY DIV RMD STRATEGIC
A5269Z1D

Characteristics

TERMINAL SURFACE TREATMENTSOLDER
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -2.00 TO 2.00
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39001
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0012
BODY HEIGHTINCHES MINIMUM 0.150 AND INCHES MAXIMUM 0.300
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
TERMINAL DIAMETERINCHES NOMINAL 0.040
SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHM-MICROFARADS 33.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 6800.000
BODY STYLE
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39001 TO 5
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0 TO 70.0
BODY LENGTHINCHES MINIMUM 0.680 AND INCHES MAXIMUM 0.780
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.425
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
TERMINAL LENGTHINCHES MINIMUM 1.000
MATERIALCASE PLASTIC
BODY WIDTHINCHES MAXIMUM 0.870

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-APR-91ZG81ZG
ZN01ZN01-JUL-17ZN81ZN
ZW01ZW01-NOV-05ZW81ZW

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
04-NOV-1977
NIIN status code
0

Request a quote