Catalog item

CAPACITOR,FIXED,GLASS DIELECTRIC

5910FSC
00NCB code
581-8250Item number
NIIN 00-581-8250
Request a quote
DEMIL code
A

Identification

Item name code
00004
PINC
0000004
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
CY15C151J81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX1D4
MILC11272-281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX1D
MS35372-1696906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX1B

Characteristics

DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0025
MATERIALCASE GLASS
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-11272
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-11272 TO 2
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -25.0 TO 25.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 150.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TERMINAL SURFACE TREATMENTSOLDER
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.125
BODY LENGTHINCHES NOMINAL 0.469
BODY WIDTHINCHES NOMINAL 0.109
BODY HEIGHTINCHES NOMINAL 0.266
TERMINAL DIAMETERINCHES NOMINAL 0.020
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
SCHEMATIC DIAGRAM DESIGNATOR
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 140.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 10000.0

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YJ01YJ01-APR-91YJ81YJ
ZR01ZR01-JUL-97ZR81ZR

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
24-DEC-1971
NIIN status code
0

Cancelled and replaced NIINs

FSC
5910
Cancelled NIIN
5910-00-614-9279
NIIN status code
7
Effective date
01-JUL-2026
DEMIL code
A

Request a quote