Catalog item
Request a quoteCAPACITOR,FIXED,CERAMIC DIELECTR
5910FSC
00NCB code
686-8963Item number
NIIN 00-686-8963
- DEMIL code
- A
Identification
- Item name code
- 00007
- PINC
- 0000007
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8532290040
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| MIL-C-20/1 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | E | ZZ | ||
| CC20CH120J | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | 4 | 48 | 3 | D |
| 416355-29 | 96214 RAYTHEON COMPANY DBA RAYTHEON | A | 5 | 1 | 5 | 48 | 3 | D |
| 916-0141-00 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | C | 1 | 5 | 48 | 3 | D |
Characteristics
| BODY LENGTH | INCHES NOMINAL 0.375 |
|---|---|
| TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | SINGLE SECTION 0.0 |
| INSULATION RESISTANCE AT REFERENCE TEMP | MEGOHMS 50000.0 |
| TERMINAL SURFACE TREATMENT | SOLDER |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| CAPACITANCE VALUE PER SECTION | PICOFARADS SINGLE SECTION 12.000 |
| SCHEMATIC DIAGRAM DESIGNATOR | |
| BODY STYLE | |
| TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | SINGLE SECTION -60.0 TO 60.0 |
| TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -5.00 TO 5.00 |
| INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | MEGOHMS 1000.0 |
| NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0 |
| TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--ILC20 |
| TERMINAL LENGTH | INCHES MINIMUM 1.250 |
| BODY DIAMETER | INCHES NOMINAL 0.180 |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 500.0 |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| YA01 | YA | 01-JAN-11 | YA | 81 | YA |
| YB01 | YB | 01-APR-91 | YB | 81 | YB |
| YD01 | YD | 01-AUG-16 | YD | 81 | YD |
| YF01 | YF | 01-FEB-16 | YF | 81 | YF |
| YJ01 | YJ | 01-APR-91 | YJ | 81 | YJ |
| YW01 | YW | 01-APR-91 | YW | 81 | YW |
| ZC01 | ZC | 01-APR-91 | ZC | 81 | ZC |
| ZG01 | ZG | 01-APR-91 | ZG | 81 | ZG |
| ZF01 | ZF | 01-NOV-95 | ZF | 81 | ZF |
| ZK01 | ZK | 01-JUL-00 | ZK | 81 | ZK |
| ZR01 | ZR | 01-JUL-97 | ZR | 81 | ZR |
| ZP01 | ZP | 01-APR-91 | ZP | 81 | ZP |
| ZU01 | ZU | 01-AUG-95 | ZU | 81 | ZU |
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW |
| VJ01 | VJ | 01-FEB-19 | VJ | 81 | VJ |
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Less than carload
- P
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 3
- Orig stdzn dec
- TX
- Dt stdzn dec
- 01-JAN-1966
- NIIN status code
- 0
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 5910 | 5910-00-197-1485 | 7 | 02-JUL-2026 | A |
| 5910 | 5910-00-858-4129 | 7 | 02-JUL-2026 | A |
Request a quote