Catalog item
Request a quoteCAPACITOR,FIXED,METALLIZED,PAPER
5910FSC
00NCB code
687-1254Item number
NIIN 00-687-1254
- DEMIL code
- A
Identification
- Item name code
- 31959
- PINC
- 0031959
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- A
- Hazardous material indicator
- P
- Schedule B export code
- 8532290040
- Last known source of supply
- S9E
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 235-9009P12 | 3B150 RAYTHEON COMPANY DBA RAYTHEON CO | A | 3 | 2 | 5 | ZZ | |||
| 235-9009P12 | 49956 RAYTHEON COMPANY DIV CORP | A | 5 | 9 | 5 | XX | 3 | B | |
| 626942-227 | 56232 LOCKHEED MARTIN CORPORATION DIV RMS - MITCHEL FIELD | A | 3 | 2 | X | XX | 3 | D | |
| 118P20592S2 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | 3 | 2 | X | XX | 3 | D | |
| MTWKN1C205K | 00853 CORNELL-DUBILIER MARKETING INC | A | C | 1 | 4 | ZZ | 3 | D | 9F |
| MTWKN1C205K | 14655 CORNELL-DUBILIER ELECTRONICS | R | 5 | 9 | 4 | 75 | 3 | B |
Characteristics
| TERMINAL LENGTH | INCHES MINIMUM 1.625 |
|---|---|
| SCHEMATIC DIAGRAM DESIGNATOR | |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| POWER FACTOR AT REFERENCE TEMP IN PERCENT | 1.0000 |
| TERMINAL SURFACE TREATMENT | SOLDER |
| BODY STYLE | |
| INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | MEGOHM-MICROFARADS 10.0 |
| CAPACITANCE VALUE PER SECTION | MICROFARADS SINGLE SECTION 2.000 |
| NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0 |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 200.0 |
| TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -10.00 TO 10.00 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.032 |
| BODY DIAMETER | INCHES NOMINAL 0.670 |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
| BODY LENGTH | INCHES NOMINAL 1.625 |
| INSULATION RESISTANCE AT REFERENCE TEMP | MEGOHM-MICROFARADS 2000.0 |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| WB01 | WB | 01-FEB-05 | WB | 81 | WB |
| YA01 | YA | 01-NOV-08 | YA | 81 | YA |
| YB01 | YB | 01-APR-91 | YB | 81 | YB |
| YD01 | YD | 01-APR-91 | YD | 81 | YD |
| ZF01 | ZF | 01-APR-91 | ZF | 81 | ZF |
| ZU01 | ZU | 01-AUG-95 | ZU | 81 | ZU |
| VJ01 | VJ | 01-DEC-18 | VJ | 81 | VJ |
Freight
- ACTY CD
- XX
Related items
Standardization
- Item standardization code
- 3
- Orig stdzn dec
- TX
- Dt stdzn dec
- 24-MAR-1968
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5910
- Cancelled NIIN
- 5910-00-704-5521
- NIIN status code
- 7
- Effective date
- 01-JUL-2026
- DEMIL code
- A