Catalog item
Request a quoteCAPACITOR,FIXED,PLASTIC DIELECTR
5910FSC
00NCB code
725-8911Item number
NIIN 00-725-8911
- DEMIL code
- A
Identification
- Item name code
- 00006
- PINC
- 0000006
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-61
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8532250080
- Last known source of supply
- S9E
Part numbers
Characteristics
| SCHEMATIC DIAGRAM DESIGNATOR | |
|---|---|
| BODY STYLE | |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 50.0 |
| TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -20.00 TO 20.00 |
| INSULATION RESISTANCE AT REFERENCE TEMP | MEGOHMS 75000.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| CAPACITANCE VALUE PER SECTION | PICOFARADS SINGLE SECTION 47000.000 |
| BODY LENGTH | INCHES MAXIMUM 0.531 |
| BODY HEIGHT | INCHES MAXIMUM 0.433 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 0.440 AND INCHES MAXIMUM 0.455 |
| DIELECTRIC MATERIAL | PLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) |
| MATERIAL | CASE PLASTIC |
| TERMINAL LENGTH | INCHES MINIMUM 1.000 |
| INTERNAL ELECTRICAL CONNECTION TYPE | EXTENDED FOIL |
| BODY WIDTH | INCHES MAXIMUM 0.235 |
| NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| YA01 | YA | 01-NOV-08 | YA | 81 | YA |
| ZG01 | ZG | 01-APR-91 | ZG | 81 | ZG |
| ZF01 | ZF | 01-APR-91 | ZF | 81 | ZF |
Freight
- ACTY CD
- XX
Related items
Standardization
- Item standardization code
- 3
- Orig stdzn dec
- TX
- Dt stdzn dec
- 03-JUL-1983
- NIIN status code
- 0
Request a quote