Catalog item

CAPACITOR,FIXED,GLASS DIELECTRIC

5910FSC
00NCB code
809-0952Item number
NIIN 00-809-0952
Request a quote
DEMIL code
A

Identification

Item name code
00004
PINC
0000004
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MILC11272-181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX3D
CY10C680F81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
4112280-24605869
RAYTHEON COMPANY DIV RMD STRATEGIC
AC16TX1D
948052-168013973
LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
RC15TX1D

Characteristics

TERMINAL DIAMETERINCHES NOMINAL 0.020
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 68.000
TERMINAL LENGTHINCHES MINIMUM 1.125
BODY LENGTHINCHES NOMINAL 0.344
BODY WIDTHINCHES NOMINAL 0.078
BODY HEIGHTINCHES NOMINAL 0.172
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-11272 TO 1C
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 140.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -25.0 TO 25.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -1.00 TO 1.00
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0025
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE GLASS
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-11272
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 10000.0
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-APR-91YB81YB
YD01YD01-AUG-16YD81YD
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-JUL-97ZR81ZR
ZW01ZW01-NOV-98ZW81ZW

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
11-SEP-1971
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59105910-00-018-3183502-JUL-2026A
59105910-00-681-1805501-JUL-2026A
59105910-00-816-3943502-JUL-2026A
59105910-00-809-7565502-JUL-2026A
59105910-00-704-5628501-JUL-2026A
59105910-00-681-9426501-JUL-2026A

Request a quote