Catalog item
Request a quoteCAPACITOR,FIXED,ELECTROLYTIC
5910FSC
00NCB code
926-9786Item number
NIIN 00-926-9786
- DEMIL code
- A
Identification
- Item name code
- 00008
- PINC
- 0000008
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 25-APR-67
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8532290040
- Last known source of supply
- SMS
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| M39003-01-2007 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | 3 | TX | 3 | D | |
| MILC39003-1 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | 3 | TX | 3 | D | |
| CSR13B157KL | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 1 | 3 | TX | 3 | D | |
| 432208055240 | H2294 THALES OPTRONICS B.V. | R | 5 | 9 | 5 | ZN | 4 | B | |
| 432208055240 | H0D18 THALES NEDERLAND, HUIZEN | A | C | 1 | 5 | ZZ | 4 | D | 9F |
| 4111957-448 | 05869 RAYTHEON COMPANY DIV RMD STRATEGIC | A | 5 | 2 | 6 | 9Z | 1 | D | |
| M39003-01-2007 | 09790 EATON AEROSPACE LLC DBA STERER ENGINEERING DIV VALVE & ACTUATOR | A | 5 | 1 | 5 | TX | 1 | D |
Characteristics
| SCHEMATIC DIAGRAM DESIGNATOR | |
|---|---|
| BODY DIAMETER | INCHES NOMINAL 0.289 |
| RELIABILITY INDICATOR | ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.0010 |
| TERMINAL LENGTH | INCHES NOMINAL 1.500 |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
| TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39003 |
| ANODE TYPE | SOLID |
| ELECTRICAL POLARIZATION | POLARIZED |
| MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-3 |
| CAPACITANCE VALUE PER SECTION | MICROFARADS SINGLE SECTION 150.000 |
| NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0 |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 6.0 |
| TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -10.00 TO 10.00 |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 8.0000 |
| DC LEAKAGE AT REFERENCE TEMP | MICROAMPERES 4.500 |
| BODY LENGTH | INCHES NOMINAL 0.686 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.025 |
| DC LEAKAGE AT MAXIMUM OPERATING TEMP | MICROAMPERES 90.0 |
| SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-C-39003 TO 1 |
| BODY STYLE | |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| WB01 | WB | 01-FEB-05 | WB | 81 | WB |
| YB01 | YB | 01-APR-91 | YB | 81 | YB |
| YD01 | YD | 01-AUG-16 | YD | 81 | YD |
| ZF01 | ZF | 01-APR-91 | ZF | 81 | ZF |
| ZG01 | ZG | 01-APR-91 | ZG | 81 | ZG |
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH |
| ZP01 | ZP | 01-APR-91 | ZP | 81 | ZP |
| ZR01 | ZR | 01-JUL-97 | ZR | 81 | ZR |
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU |
| ZW01 | ZW | 01-NOV-05 | ZW | 81 | ZW |
| VJ01 | VJ | 01-DEC-18 | VJ | 81 | VJ |
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- E
- Orig stdzn dec
- TX
- Dt stdzn dec
- 11-OCT-1972
- NIIN status code
- 0
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 5910 | 5910-00-880-7239 | 5 | 02-JUL-2026 | A |
| 5910 | 5910-00-728-3137 | 5 | 02-JUL-2026 | A |
| 5910 | 5910-00-926-8131 | 5 | 02-JUL-2026 | A |
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.