Catalog item

CAPACITOR,FIXED,GLASS DIELECTRIC

5910FSC
00NCB code
988-3517Item number
NIIN 00-988-3517
Request a quote
DEMIL code
A

Identification

Item name code
00004
PINC
0000004
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-62
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
CY15C361F81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22XXX3D
MILC11272-281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41XXX3D
4112280-22982577
RAYTHEON COMPANY DBA RAYTHEON
A51XXX3D
4112280-22905869
RAYTHEON COMPANY DIV RMD STRATEGIC
A51XXX3D

Characteristics

QUALITY FACTOR AT REFERENCE TEMP1400.0000
BODY STYLE
BODY HEIGHTINCHES NOMINAL 0.266
TERMINAL LENGTHINCHES MINIMUM 1.125
SCHEMATIC DIAGRAM DESIGNATOR
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL SURFACE TREATMENTSOLDER
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 360.000
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--ILC11272
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
MATERIALCASE GLASS
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -1.00 TO 1.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
BODY LENGTHINCHES NOMINAL 0.469
BODY WIDTHINCHES NOMINAL 0.109
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -25.0 TO 25.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 140.0
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YA01YA01-FEB-01YA81YA
YD01YD01-AUG-16YD81YD
ZH01ZH01-APR-91ZH81ZH
ZU01ZU01-APR-08ZU81ZU

Freight

ACTY CD
XX

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
12-JAN-1973
NIIN status code
0

Cancelled and replaced NIINs

FSC
5910
Cancelled NIIN
5910-00-815-4362
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.