Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
00NCB code
995-2881Item number
NIIN 00-995-2881
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290020
Last known source of supply
S9E

Part numbers

Part number
DM10C100J100V
CAGE
72136
ELECTRO MOTIVE CORP SUBSIDIARY OF INTERNATIONAL ELECTRONICS CORP
CAGE status
H
RNCC
3
RNVC
9
Document availability code
X
RNAAC
XX
RNFC
3
RNSC
D

Characteristics

CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.225
BODY LENGTHINCHES NOMINAL 0.438
BODY WIDTHINCHES NOMINAL 0.390
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 100.0
RELIABILITY INDICATORNOT ESTABLISHED
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 10000.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -200.0 TO 200.0
TERMINAL SURFACE TREATMENTSOLDER
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 10.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 100.0
BODY STYLE
MATERIALCASE CERAMIC
TERMINAL LENGTHINCHES MINIMUM 1.000
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
BODY HEIGHTINCHES NOMINAL 0.225

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-APR-91YB81YB
ZU01ZU01-AUG-95ZU81ZU

Freight

ACTY CD
XX

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
10-MAR-1969
NIIN status code
0

Request a quote