Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
01NCB code
004-3261Item number
NIIN 01-004-3261
Request a quote
DEMIL code
A

Identification

Item name code
00008
PINC
0000008
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
10-JUN-75
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-C-39006/981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX1D
M39006/09-860181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX1D

Characteristics

BODY STYLE
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-3 AND C
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
TERMINAL LENGTHINCHES NOMINAL 1.500
BODY DIAMETERINCHES MAXIMUM 0.219
BODY LENGTHINCHES NOMINAL 0.515
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
ANODE TYPESOLID
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS1250.0
ELECTRICAL POLARIZATIONPOLARIZED
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 1.700
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
DC LEAKAGE AT MAXIMUM OPERATING TEMPMICROAMPERES 2.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 125.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
CAPACITIVE ELECTRODE MATERIALTANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT7.0000
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 1.000
CASE INSULATION MATERIALPLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39006
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39006 TO 9

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
VJ01VJ01-MAR-19VJ81VJ
ZW01ZW01-DEC-95ZW81ZW

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
03-MAR-1978
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.