Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
01NCB code
033-3501Item number
NIIN 01-033-3501
Request a quote
DEMIL code
A

Identification

Item name code
00008
PINC
0000008
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
29-DEC-76
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
MILC39003-381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX1D
M39003-03-026481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX1D
2106W23P07097424
AMETEK INC DIV AEROSPACE AND DEFENSE
AC16TXAW

Characteristics

BODY STYLE
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-3
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
TERMINAL LENGTHINCHES NOMINAL 1.500
BODY DIAMETERINCHES NOMINAL 0.135
BODY LENGTHINCHES NOMINAL 0.286
TERMINAL DIAMETERINCHES NOMINAL 0.020
SCHEMATIC DIAGRAM DESIGNATOR
ANODE TYPESOLID
ELECTRICAL POLARIZATIONPOLARIZED
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 1.800
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
DC LEAKAGE AT MAXIMUM OPERATING TEMPMICROAMPERES 10.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 35.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -10.00 TO 10.00
CAPACITIVE ELECTRODE MATERIALTANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT4.0000
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 1.000
CASE INSULATION MATERIALPLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39003
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39003 TO 3

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-APR-91YB81YB
YD01YD01-AUG-16YD81YD
ZC01ZC01-APR-91ZC81ZC

Freight

ACTY CD
TX

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
10-MAR-1978
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.