Catalog item

CAPACITOR,FIXED,CERAMIC DIELECTR

5910FSC
01NCB code
075-2192Item number
NIIN 01-075-2192
Request a quote
DEMIL code
A

Identification

Item name code
00007
PINC
0000007
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
17-APR-79
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
MIL-C-20/3681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX4D
CCR06CG152GR81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D
CCR06CG152KM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
913-3281-14013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
AC11TX4DAW
8131-100C0G152K18796
MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
HC15TX4DAW

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.0100
TERMINAL LENGTHINCHES MINIMUM 1.250
BODY LENGTHINCHES NOMINAL 0.290
BODY WIDTHINCHES NOMINAL 0.290
BODY HEIGHTINCHES NOMINAL 0.090
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.200
TERMINAL DIAMETERINCHES MINIMUM 0.020 AND INCHES MAXIMUM 0.027
SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 10000.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 1500.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 200.0
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -30.0 TO 30.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -2.00 TO 2.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.1500
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-20
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-20 TO 36

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YA01YA01-JAN-11YA81YA
YB01YB01-SEP-09YB81YB
YJ01YJ01-MAY-16YJ81YJ
YW01YW01-MAY-00YW81YW
ZU01ZU01-JUL-05ZU81ZU

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
13-JUL-1985
NIIN status code
0

Request a quote