Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
01NCB code
096-0470Item number
NIIN 01-096-0470
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
12-JUN-80
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8532290020
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-C-39001/581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A4149Z1D
CMR08F473JPDM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A2249Z1D

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
TERMINAL LENGTHINCHES MINIMUM 1.000
BODY LENGTHINCHES MINIMUM 1.360 AND INCHES MAXIMUM 1.470
BODY WIDTHINCHES NOMINAL 0.910
BODY HEIGHTINCHES MINIMUM 0.250 AND INCHES MAXIMUM 0.450
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.050
TERMINAL DIAMETERINCHES NOMINAL 0.040
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 47.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 150.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0 TO 70.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHM-MICROFARADS 1000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0010
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39001 TO 5
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2

MOE rules

MOE rule
ZH01
MOE CD
ZH
Date assigned
01-APR-91
PICA
ZH
PICA LOA
81
Auth collab
ZH

Freight

ACTY CD
ZG

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
27-NOV-1981
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.