Catalog item

CAPACITOR,FIXED,GLASS DIELECTRIC

5910FSC
01NCB code
100-7840Item number
NIIN 01-100-7840
Request a quote
DEMIL code
A

Identification

Item name code
00004
PINC
0000004
Criticality code
X
II
M
DEMIL code
A
NIIN assigned
13-SEP-80
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
40-1242334-127361
BURKE PRODUCTS INC
A525TX
M23269/01-309181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A514HD4A
40-1242334-107397
GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
A391HD4A
CYR10C101FM16299
AVX CORP RALEIGH PLANT
H5969Z4B1

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
TERMINAL LENGTHINCHES MINIMUM 1.125
BODY LENGTHINCHES NOMINAL 0.344
BODY WIDTHINCHES NOMINAL 0.078
BODY HEIGHTINCHES NOMINAL 0.172
TERMINAL DIAMETERINCHES NOMINAL 0.020
SCHEMATIC DIAGRAM DESIGNATOR
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 100.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 140.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -25.0 TO 25.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -0.50 TO 0.50
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.1000
MATERIALCASE GLASS
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-23269
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2

MOE rules

MOE rule
YD01
MOE CD
YD
Date assigned
01-NOV-16
PICA
YD
PICA LOA
81
Auth collab
YD

Freight

ACTY CD
HD
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
13-SEP-1980
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.