Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
01NCB code
165-7805Item number
NIIN 01-165-7805
Request a quote
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
04-NOV-83
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290020

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-C-5/1881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59E9Z4B
CM08FD303JP381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A2249Z4D
MIL-PRF-5/1881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.000
BODY LENGTHINCHES MINIMUM 1.330 AND INCHES MAXIMUM 1.440
BODY WIDTHINCHES NOMINAL 0.890
BODY HEIGHTINCHES MINIMUM 0.180 AND INCHES MAXIMUM 0.350
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.050
TERMINAL DIAMETERINCHES NOMINAL 0.040
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 0.030
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 150.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0 TO 70.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHM-MICROFARADS 1000.0
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-5 TO 18

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YA01YA01-JUL-01YA81YA
ZG01ZG01-APR-91ZG81ZG

Freight

ACTY CD
ZG

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
04-NOV-1983
NIIN status code
0

Request a quote