Catalog item

CAPACITOR,FIXED,CERAMIC DIELECTR

5910FSC
01NCB code
175-2791Item number
NIIN 01-175-2791
Request a quote
DEMIL code
A

Identification

Item name code
00007
PINC
0000007
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
29-MAR-84
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
M39014/21-001381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A2249Z4D
MIL-PRF-39014/2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-C-39014/2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A5949Z4B

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
TERMINAL LENGTHINCHES MINIMUM 1.250
BODY DIAMETERINCHES MINIMUM 0.080 AND INCHES MAXIMUM 0.100
BODY LENGTHINCHES MINIMUM 0.230 AND INCHES MAXIMUM 0.250
TERMINAL DIAMETERINCHES MINIMUM 0.015 AND INCHES MAXIMUM 0.019
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 820.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 50.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39014
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39014 TO 21

MOE rules

MOE rule
ZC01
MOE CD
ZC
Date assigned
01-APR-91
PICA
ZC
PICA LOA
81
Auth collab
ZC

Freight

ACTY CD
ZG

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
18-JAN-1986
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.