Catalog item

CAPACITOR,FIXED,METALLIZED,PAPER

5910FSC
01NCB code
262-5861Item number
NIIN 01-262-5861
Request a quote
DEMIL code
A

Identification

Item name code
31959
PINC
0031959
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
31-AUG-87
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
F410E394S572928
GULTON INDUSTRIES INC GUDEMAN DIV
HE83TX1D
MIL-PRF-39022/1081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-C-39022/1081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
M39022/10G394JS81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EZZ
M39022/10-G394JR81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
TERMINAL LENGTHINCHES MINIMUM 1.625
BODY DIAMETERINCHES NOMINAL 0.593
BODY LENGTHINCHES NOMINAL 1.593
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 25000.0
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 0.390
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 400.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 250000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.250
TERMINAL SURFACE TREATMENTSOLDER
CASE INSULATION MATERIALPLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39022
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39022 TO 10

MOE rules

MOE rule
YB01
MOE CD
YB
Date assigned
01-OCT-96
PICA
YB
PICA LOA
81
Auth collab
YB

Freight

ACTY CD
TX

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5910-01-091-4562ETX08-DEC-19920
BTX11-DEC-19920
ETX08-DEC-19920

Cancelled and replaced NIINs

FSC
5910
Cancelled NIIN
5910-01-021-1520
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote