Catalog item

CAPACITOR,FIXED,METALLIZED,PAPER

5910FSC
01NCB code
329-0392Item number
NIIN 01-329-0392
Request a quote
DEMIL code
A

Identification

Item name code
31959
PINC
0031959
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
11-NOV-90
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
CFR12RRK222JS81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A2249Z4D
MIL-PRF-55514/881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
CFR12RRK222JM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A5949Z4B
MIL-C-55514/881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A5949Z4B

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
TERMINAL LENGTHINCHES MINIMUM 1.250
BODY LENGTHINCHES NOMINAL 0.190
BODY WIDTHINCHES NOMINAL 0.190
BODY HEIGHTINCHES NOMINAL 0.090
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.200
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 7000.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 2200.000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 250.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 500000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.3000
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-55514
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-55514 TO 8

MOE rules

MOE rule
ZG01
MOE CD
ZG
Date assigned
01-APR-91
PICA
ZG
PICA LOA
81
Auth collab
ZG

Freight

ACTY CD
ZG

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
11-NOV-1990
NIIN status code
0

Request a quote