Catalog item

CAPACITOR,FIXED,METALLIZED,PAPER

5910FSC
01NCB code
552-4362Item number
NIIN 01-552-4362
Request a quote
DEMIL code
A

Identification

Item name code
31959
PINC
0031959
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
13-JUN-07
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
ESD/EMI code
A
Schedule B export code
8532290040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
M39022/10J224JR81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EZZ
MIL-C-39022/1081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A5949Z4B
MIL-PRF-39022/1081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
TERMINAL LENGTHINCHES MINIMUM 1.625
BODY DIAMETERINCHES MINIMUM 0.557 AND INCHES MAXIMUM 0.577
BODY LENGTHINCHES MINIMUM 1.781 AND INCHES MAXIMUM 1.843
TERMINAL DIAMETERINCHES NOMINAL 0.032
SCHEMATIC DIAGRAM DESIGNATOR
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 15000.0
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 0.220
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 600.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 250000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.250
CASE INSULATION MATERIALPLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39022
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39022 TO 10

MOE rules

MOE rule
ZR01
MOE CD
ZR
Date assigned
01-JUN-07
PICA
ZR
PICA LOA
81
Auth collab
ZR

Freight

ACTY CD
EI

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
13-JUN-2007
NIIN status code
0

Request a quote