Catalog item

FUSE LINK,ELECTRICAL

5920FSC
00NCB code
106-5423Item number
NIIN 00-106-5423
Request a quote
DEMIL code
A

Identification

Item name code
04185
PINC
0004185
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
15-JUL-68
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8535100020

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
9F51CAT03024446
GENERAL ELECTRIC COMPANY
A596TX1B
9F51CAT03003538
LOCKHEED MARTIN CORPORATION DIV RMS
A326TX4D

Characteristics

CIRCUIT OVER-CURRENT INTERRUPTION TYPETIME DELAY
OVERALL DIAMETERINCHES MINIMUM 0.500 AND INCHES MAXIMUM 0.750
CONTINUOUS CURRENT RATING IN AMPS30.000
TERMINAL DIAMETERINCHES NOMINAL 0.125
MAXIMUM VOLTAGE RATING IN VOLTSAC 15000.0
TERMINAL LENGTHINCHES NOMINAL 15.000
INTERRUPTION INDICATOR METHODVISIBLE ELEMENT
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS200 PCT OF CURRENT RATING 300.0
OVERALL LENGTHINCHES NOMINAL 20.000
BODY STYLE

MOE rules

MOE rule
G170
MOE CD
T1
AMC
0
AMSC
0
Date assigned
01-APR-91
Acquisition advice code
C
PICA
17
PICA LOA
48
Auth collab
17 75

Freight

ACTY CD
17

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
AA
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
XX
Cush dun
XX
THK
X
Unit cont
YY
PKG data source
A

Unit pack

PICA SICA
P
Inter cont
D4
Vendor's setup or folding box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
06-SEP-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.