Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
009-7212Item number
NIIN 00-009-7212
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
29-JUL-72
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
JA1C3-2-5-3A74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H596KE4B
JA1-C3-2.5-250VAC-3-400HZ74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H395TX
C300-016K0233
THALES UK LIMITED DBA THALES UK LTD OPTRONICS
R595KE3B
JAIC3-2-5-3AS4702
EATON INDUSTRIES MANUFACTURING
A525KE
C300-016K0216
THALES UK LIMITED DBA THALES UK LTD OPTRONICS
A525ZZD

Characteristics

MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
TERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 2
THREAD QUANTITY PER INCH32
BODY LENGTHINCHES MINIMUM 1.985 AND INCHES MAXIMUM 2.015
BODY WIDTHINCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
BODY STYLE
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
ACTUATOR FUNCTIONTRIP-RESET
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.655 AND INCHES MAXIMUM 1.665
FRAGILITY FACTORMODERATELY RUGGED
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 250.0
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
BOSS HEIGHTINCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.135
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.875 AND INCHES MAXIMUM 1.885
POLE QUANTITY1
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 2.800 AND MAXIMUM AT 200 PCT 25.000
RESET METHODMANUAL
NOMINAL THREAD SIZEINCHES 0.138
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 2.5
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.555 AND INCHES MAXIMUM 1.565
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
ACTUATOR POSITION DESIGNATIONAT POLE ONE

MOE rules

MOE rule
YB01
MOE CD
YB
Date assigned
01-APR-91
PICA
YB
PICA LOA
81
Auth collab
YB

Freight

ACTY CD
98
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HY
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
16-JAN-1981
NIIN status code
0

Request a quote