Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
00NCB code
012-4396Item number
NIIN 00-012-4396
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-61
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
- Last known source of supply
- SMS
Part numbers
Characteristics
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
|---|---|
| BODY LENGTH | INCHES NOMINAL 10.125 |
| BODY WIDTH | INCHES NOMINAL 5.000 |
| TRIP RELEASE AMBIENT TEMP RATING | ALL LOCATIONS CELSIUS NOMINAL 40.0 |
| FREQUENCY IN HERTZ | 60.0 |
| MATERIAL | CASE PLASTIC |
| TERMINAL TYPE AND QUANTITY | THREADED STUD 6 |
| POLE QUANTITY | 3 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| TRIP RELEASE METHOD | ALL LOCATIONS THERMAL-MAGNETIC |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| ACTUATOR FUNCTION | TRIP-RESET |
| BODY STYLE | |
| ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MINIMUM AT 200 PCT 170.000 AND MAXIMUM AT 200 PCT 460.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 70.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 600.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 25000.0 |
| MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 6 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BOSS HEIGHT | INCHES NOMINAL 0.500 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 13.631 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 1.719 |
| UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.250 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 8.438 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 8.875 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 1.719 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| YB01 | YB | 01-SEP-08 | YB | 81 | YB |
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH |
| ZJ01 | ZJ | 01-MAY-22 | ZJ | 81 | ZJ |
| ZR01 | ZR | 01-OCT-98 | ZR | 81 | ZR |
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU |
| VJ01 | VJ | 01-DEC-18 | VJ | 81 | VJ |
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- C
- Orig stdzn dec
- TX
- Dt stdzn dec
- 06-SEP-1971
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.