Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
00NCB code
173-7650Item number
NIIN 00-173-7650
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
- Last known source of supply
- S9E
Part numbers
Characteristics
| BODY STYLE | |
|---|---|
| OVERALL LENGTH | INCHES NOMINAL 2.000 |
| BODY WIDTH | INCHES NOMINAL 1.343 |
| INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 5.000 AND MAXIMUM AT 200 PCT 55.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
| TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 25.0 |
| UNPACKAGED UNIT WEIGHT | OUNCES NOMINAL 1.000 |
| FREQUENCY IN HERTZ | 60.0 |
| MATERIAL | CASE PLASTIC |
| TERMINAL TYPE AND QUANTITY | TAB W/SCREW 2 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 575.0 AND DC 875.0 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 0.906 |
| UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.250 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.574 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 1.234 |
| POLE QUANTITY | 1 |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 2 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 2.0 AND AMPERES DC 2.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 110.0 AND DC 30.0 |
| RESET METHOD | AUTOMATIC |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| WB01 | WB | 01-FEB-05 | WB | 81 | WB |
| YB01 | YB | 01-JUL-03 | YB | 81 | YB |
| YD01 | YD | 01-AUG-16 | YD | 81 | YD |
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU |
| ZW01 | ZW | 01-NOV-05 | ZW | 81 | ZW |
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Less than carload
- P
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 3
- Orig stdzn dec
- TX
- Dt stdzn dec
- 19-DEC-1965
- NIIN status code
- 0
Request a quote