Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
261-7926Item number
NIIN 00-261-7926
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
15-JUL-73
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
SM33-10-50VDC174193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
HC1ETXAF
HE2B3-10-174193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
HC1ETXAF
HB2Z1-5274193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
HC15TXAF
HE2Z6-5274193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
HC15TXAF
M39019/03-5281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX
MIL-C-39019/381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41ETX
AP12-1-5-2-10381541
SENSATA TECHNOLOGIES MARYLAND, INC
AC1ETXAF
ASC1265301Z4779
ASC PTY LTD
A599ZA4B

Characteristics

BODY STYLE
BUSHING LENGTHINCHES MAXIMUM 0.380
BODY LENGTHINCHES MAXIMUM 1.562
POLE QUANTITY2
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.490 AND MAXIMUM AT 200 PCT 10.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES DC 10.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.594 AND INCHES MAXIMUM 0.656
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.828
TERMINAL TYPE AND QUANTITYWIRE HOOK 4
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39019 TO 3
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 50.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS DC 500.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.375
BODY WIDTHINCHES MAXIMUM 1.281
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39019
THREAD SERIES DESIGNATORUNEF
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MAXIMUM 0.906

MOE rules

MOE rule
ZA01
MOE CD
ZA
Date assigned
01-APR-91
PICA
ZA
PICA LOA
81
Auth collab
ZA

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
09-SEP-1976
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.