Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
401-7685Item number
NIIN 00-401-7685
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
03-APR-70
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
G330001-2824930
L3HARRIS TECHNOLOGIES, INC DIV SPACE & AIRBORNE SYSTEMS
A52ATX3D
AM12MG6-2-250VAC474193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ETX
APL1-1-62-202-M81541
SENSATA TECHNOLOGIES MARYLAND, INC
A52ETX
APL1-532-27081541
SENSATA TECHNOLOGIES MARYLAND, INC
A52ETX3D
4MC2-104-282647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
A52ETX3D
APL1-26-2881541
SENSATA TECHNOLOGIES MARYLAND, INC
A52ETX3D
260-4007-27013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A32ATX3D

Characteristics

CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.938
FRAGILITY FACTORMODERATELY RUGGED
THREAD QUANTITY PER INCH32
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.062
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
BODY WIDTHINCHES NOMINAL 0.750
THREAD PITCH DIAMETERSINCHES 0.1177 TO 0.1214
BODY STYLE
BODY LENGTHINCHES NOMINAL 2.500
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 2.0
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
POLE QUANTITY1
TERMINAL TYPE AND QUANTITYTHREADED STUD 2
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 10.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
FREQUENCY IN HERTZ60.0
BOSS HEIGHTINCHES NOMINAL 0.140
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.611
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ACTUATOR POSITION DESIGNATIONAT POLE ONE
RESET METHODMANUAL
NOMINAL THREAD SIZEINCHES 0.138

MOE rules

MOE rule
ZC01
MOE CD
ZC
Date assigned
01-APR-91
PICA
ZC
PICA LOA
81
Auth collab
ZC

Freight

ACTY CD
TX

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
18-JUN-1973
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.