Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
444-2590Item number
NIIN 00-444-2590
Request a quote
Unit price
$189.33
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
18-DEC-70
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Management

Effective date
01-JUL-2025
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$189.33
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
63213-882340
L3HARRIS TECHNOLOGIES, INC.
A321HH3D
7234-34-482647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
A595HH3B
7274-34-482647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
AC16ZZAC

Characteristics

MATERIALCASE PLASTIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 4.0 AND AMPERES DC 4.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 120.0 AND DC 30.0
BODY LENGTHINCHES NOMINAL 0.750
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND EXPLOSION PROOF
TRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
FREQUENCY IN HERTZ400.0
BODY STYLE
BUSHING LENGTHINCHES NOMINAL 0.359
NOMINAL THREAD SIZEINCHES 0.469
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.219
POLE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
THREAD SERIES DESIGNATORUN
TERMINAL TYPE AND QUANTITYSCREW 2
ACTUATOR POSITION DESIGNATIONAT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT145.0
ULTIMATE TRIP TIME PER POLE IN SECONDSSINGLE LOCATION MINIMUM 2.000 AND MAXIMUM 20.000
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
ACTUATOR FUNCTIONTRIP-RESET
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 800.0
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
TRIP RELEASE METHODSINGLE LOCATION THERMAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.593
BODY WIDTHINCHES NOMINAL 0.562

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YA01YA01-JAN-02YA81YA
YD01YD01-AUG-16YD81YD
ZW01ZW01-NOV-98ZW81ZW

Management phrases

Major organizational entity
DS
USC
I
Phrase code
V
Phrase
DISCONTINUED WITHOUT REPLACEMENT
Quantity per assembly
0

Freight

ACTY CD
HH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
10-MAY-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.