Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
454-9232Item number
NIIN 00-454-9232
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
21-MAY-71
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
AM12MG6-30-250-54-6074193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H39ETX
AM12MG6-30A250V60CPS474193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ETX3D

Characteristics

THREAD QUANTITY PER INCH32
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.611
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.938
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.062
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
POLE QUANTITY1
ARC QUENCHING METHODMAGNETIC BLOWOUT
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 2
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 10.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 4.250
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
FREQUENCY IN HERTZ60.0
MATERIALCASE PLASTIC
BODY STYLE
BODY LENGTHINCHES NOMINAL 2.500
BODY WIDTHINCHES NOMINAL 0.750
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 30.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0
BOSS HEIGHTINCHES NOMINAL 0.140
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
RESET METHODMANUAL
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZG01ZG01-APR-91ZG81ZG
ZW01ZW01-NOV-05ZW81ZW

Freight

ACTY CD
ZG
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
5
Air dimension code
A
Air commodity code
HY
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
18-JUN-1973
NIIN status code
0

Request a quote