Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
00NCB code
462-5506Item number
NIIN 00-462-5506
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 30-MAY-74
- Precious metals indicator
- A
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
- Last known source of supply
- S9E
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| M39019/4-40 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | E | TX | 4 | D |
| MILC39019-4 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | 4 | 9Z | 3 | D |
| 352250009234 | H0203 THALES NEDERLAND | A | 5 | 2 | E | TX | 3 | D |
Characteristics
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 300.0 |
|---|---|
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING WITH PANEL SEAL 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| THREAD QUANTITY PER INCH | 32 |
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| TERMINAL TYPE AND QUANTITY | WIRE HOOK 4 |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE TWO |
| TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC-HYDRAULIC |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | ALL LOCATIONS MAXIMUM 60.000 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| ACTUATOR FUNCTION | TRIP-RESET |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 3.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 240.0 |
| BODY STYLE | |
| BUSHING LENGTH | INCHES NOMINAL 0.330 |
| BODY LENGTH | INCHES MAXIMUM 1.562 |
| BODY WIDTH | INCHES MAXIMUM 1.281 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MAXIMUM 0.906 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 0.625 |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MAXIMUM 1.828 |
| POLE QUANTITY | 2 |
| FREQUENCY IN HERTZ | 400.0 |
| TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL39019 TO 4 |
| THREAD SERIES DESIGNATOR | UNEF |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MINIMUM AT 200 PCT 0.500 AND MAXIMUM AT 200 PCT 9.000 |
| SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
| SWITCH CURRENT RATING AND TYPE IN AMPS | AC 0.5 AND DC 0.5 |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 120.0 AND DC 50.0 |
| INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | CONTROL 1 |
| NOMINAL THREAD SIZE | INCHES 0.375 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU |
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW |
Freight
- ACTY CD
- ZG
Related items
Standardization
- Item standardization code
- E
- Orig stdzn dec
- TX
- Dt stdzn dec
- 19-JAN-1979
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.