Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
498-1859Item number
NIIN 00-498-1859
Request a quote
Unit price
$342.52
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
10-OCT-69
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Management

Effective date
01-JUL-2025
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$342.52
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
17-13936-580070
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN ROTARY AND MISSION SYSTEMS DIV RMS- MIC2
A59ATX3B
7276-104-282647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
A32ATX3D
17-13936-504614
TEXTRON SYSTEMS CORPORATION DBA TEXTRON SYSTEMS CORP
AC16ZZAC

Characteristics

TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 25.0
SWITCH TERMINAL TYPETAB, SOLDER LUG
TRIP RELEASE METHODALL LOCATIONS THERMAL
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.469
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE THREE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 35.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
THREAD SERIES DESIGNATORUNS
TERMINAL TYPE AND QUANTITYSCREW 6
POLE QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWO
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.341
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.850
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.841
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.560
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT145.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
BODY STYLE
BUSHING LENGTHINCHES MAXIMUM 0.280
BODY LENGTHINCHES MAXIMUM 2.000
BODY WIDTHINCHES MAXIMUM 0.850
BODY HEIGHTINCHES MAXIMUM 2.765
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 120.0 AND DC 28.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 2500.0 AND DC 2500.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
MATERIALCASE PLASTIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 2.0 AND AMPERES DC 2.0
FREQUENCY IN HERTZ400.0
SWITCH CURRENT RATING AND TYPE IN AMPSAC 7.0 AND DC 4.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 130.0 AND DC 28.0

MOE rules

MOE rule
YB01
MOE CD
YB
Date assigned
01-APR-91
PICA
YB
PICA LOA
81
Auth collab
YB

Management phrases

Major organizational entity
DS
USC
I
Phrase code
V
Phrase
DISCONTINUED WITHOUT REPLACEMENT
Quantity per assembly
0

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
17-JUL-1970
NIIN status code
0

Request a quote