Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
502-0978Item number
NIIN 00-502-0978
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
74-648-7-5-6-20074193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H395TX3D
613415-498897
LOCKHEED MARTIN CORP DIV LOCKHEED MARTIN AERONAUTICS COMPANY
A525TXD

Characteristics

ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010
POLE QUANTITY3
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.802 AND INCHES MAXIMUM 1.822
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
FRAGILITY FACTORMODERATELY RUGGED
BODY STYLE
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BODY WIDTHINCHES MINIMUM 2.263 AND INCHES MAXIMUM 2.283
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.180 AND INCHES MAXIMUM 1.200
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS AND TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
ULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS NOMINAL 3000.000
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 7.5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 200.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 3000.0
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYSCREW 6
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
FREQUENCY IN HERTZ522.0
MATERIALCASE PLASTIC
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.164
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS NOMINAL AT 200 PCT 80.000

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZR01ZR01-DEC-07ZR81ZR
ZU01ZU01-APR-91ZU81ZU
VJ01VJ01-FEB-19VJ81VJ

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
10-MAY-1971
NIIN status code
0

Request a quote