Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
584-6298Item number
NIIN 00-584-6298
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
21-DEC-74
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MILC39019-481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A4149Z3D
M39019/4-2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D
352250009226H0203
THALES NEDERLAND
A523ZG3D

Characteristics

MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
SWITCH CURRENT RATING AND TYPE IN AMPSAC 0.5 AND DC 0.5
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 120.0 AND DC 50.0
BUSHING LENGTHINCHES MAXIMUM 0.380
BODY LENGTHINCHES MAXIMUM 1.562
ACTUATOR FUNCTIONTRIP-RESET
BODY STYLE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.055 AND MAXIMUM AT 200 PCT 0.950 AND MAXIMUM AT 400 PCT 0.240 AND MAXIMUM AT 600 PCT 0.130 AND MAXIMUM AT 800 PCT 0.060
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 50.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS DC 500.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
ULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS MINIMUM 0.200 AND MAXIMUM 7.000
RESET METHODMANUAL
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
THREAD QUANTITY PER INCH32
BODY WIDTHINCHES MAXIMUM 1.281
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE TWO
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.828
POLE QUANTITY2
SWITCH TERMINAL TYPETAB, SOLDER LUG
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES DC 1.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MAXIMUM 0.906
NOMINAL THREAD SIZEINCHES 0.375
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--ILC39019-4
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
THREAD SERIES DESIGNATORUNEF
TERMINAL TYPE AND QUANTITYWIRE HOOK 4
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE

MOE rules

MOE rule
ZW01
MOE CD
ZW
Date assigned
01-NOV-98
PICA
ZW
PICA LOA
81
Auth collab
ZW

Freight

ACTY CD
ZG
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
19-JAN-1979
NIIN status code
0

Request a quote