Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
691-0019Item number
NIIN 00-691-0019
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-61
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
76-103-474193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H595TX3B
860028-2706481
NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN SYSTEMS CORP
A325ZZ
860028-2713973
LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
R395TX3D
DMS CASE 83-059B16236
DLA WEAPONS SUPPORT (COLUMBUS) DBA DLA VENDOR ITEM DRAWING (VID) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A595TX

Characteristics

MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
THREAD QUANTITY PER INCH32
BODY STYLE
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BODY WIDTHINCHES MINIMUM 2.263 AND INCHES MAXIMUM 2.283
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
NOMINAL THREAD SIZEINCHES 0.164
TERMINAL TYPE AND QUANTITYSCREW 6
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.180 AND INCHES MAXIMUM 1.200
ARC QUENCHING METHODAIR
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.802 AND INCHES MAXIMUM 1.822
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 208.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 3500.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
ULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS MAXIMUM 340.000
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 10.0
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 18.000 AND MAXIMUM AT 200 PCT 70.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
FREQUENCY IN HERTZ400.0
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010
POLE QUANTITY3
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MATERIALCASE PLASTIC

MOE rules

MOE rule
WG01
MOE CD
WG
Date assigned
01-NOV-17
PICA
WG
PICA LOA
81
Auth collab
WG

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
21-DEC-1969
NIIN status code
0

Request a quote