Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
764-2911Item number
NIIN 00-764-2911
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
06-MAR-68
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
6752-302-1082647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
A525TX3D
711525-3405869
RAYTHEON COMPANY DIV RMD STRATEGIC
A32ATX3D

Characteristics

SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 1.490 AND INCHES MAXIMUM 1.510
ACTUATOR FUNCTIONTRIP-RESET
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB W/SCREW 6
BODY WIDTHINCHES MAXIMUM 2.250
BODY HEIGHTINCHES MINIMUM 2.440 AND INCHES MAXIMUM 2.500
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.158 AND INCHES MAXIMUM 1.218
ACTUATOR POSITION DESIGNATIONAT EACH POLE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 10.000 AND MAXIMUM AT 200 PCT 75.000
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 2.100
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 1.490 AND INCHES MAXIMUM 1.510
FREQUENCY IN HERTZ400.0
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 4200.0 AND DC 6000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.782 AND INCHES MAXIMUM 1.842
NOMINAL THREAD SIZEINCHES 0.138
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE THREE
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 10.0 AND AMPERES DC 10.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 205.0 AND DC 28.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS MAXIMUM 40.0
SWITCH TERMINAL TYPETURRET
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
RESET METHODMANUAL
FRAGILITY FACTORMODERATELY RUGGED
POLE QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
BODY STYLE
BUSHING LENGTHINCHES MINIMUM 0.235 AND INCHES MAXIMUM 0.250
BODY LENGTHINCHES MAXIMUM 2.189
SWITCH CURRENT RATING AND TYPE IN AMPSDC 7.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSDC 28.0
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-APR-91YB81YB
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-APR-91ZU81ZU

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
03-OCT-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.