Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
777-4083Item number
NIIN 00-777-4083
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-60
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
3XAM17-50-120-400-5574193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H39ETX3D
10018729-50818876
US ARMY AVIATION AND MISSILE COMMAND
A525TX3D

Characteristics

BODY WIDTHINCHES MINIMUM 2.263 AND INCHES MAXIMUM 2.283
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
FRAGILITY FACTORMODERATELY RUGGED
BODY STYLE
BUSHING LENGTHINCHES MINIMUM 0.146 AND INCHES MAXIMUM 0.166
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 120.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 3500.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 2.800 AND MAXIMUM AT 200 PCT 8.500
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.802 AND INCHES MAXIMUM 1.822
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010
POLE QUANTITY3
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB W/SCREW 6
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 50.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.180 AND INCHES MAXIMUM 1.200
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
MATERIALCASE PLASTIC
FREQUENCY IN HERTZ400.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
STORAGE TYPEGENERAL PURPOSE WAREHOUSE

Freight

ACTY CD
XX

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
17-JUL-1970
NIIN status code
6

History

Identification changes

Item name code
00136
Item standardization code
2
DEMIL code
A
Criticality code
X
Precious metals indicator
U
Cancelled date
16-JUN-2026
NIIN status code
6

Past part numbers

Part numberCAGERNCCRNVC
10018729-50818876
US ARMY AVIATION AND MISSILE COMMAND
52
3XAM17-50-120-400-5574193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
39
3XAM17-50-120-400-5574193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
32

Request a quote