Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
00NCB code
822-0261Item number
NIIN 00-822-0261
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
- Last known source of supply
- S9E
Part numbers
Characteristics
| BODY WIDTH | INCHES NOMINAL 0.750 |
|---|---|
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC-HYDRAULIC |
| BODY LENGTH | INCHES NOMINAL 2.500 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 1.938 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.062 |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| BOSS HEIGHT | INCHES NOMINAL 0.140 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 2.471 |
| NOMINAL THREAD SIZE | INCHES 0.138 |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 125.0 AND DC 50.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 2 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | SINGLE LOCATION MINIMUM 0.700 AND MAXIMUM 2.800 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION DC 3000.0 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND FUNGUS RESISTANT AND EXPLOSION RESISTANT |
| THREAD QUANTITY PER INCH | 32 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 10.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION DC 28.0 |
| TERMINAL TYPE AND QUANTITY | THREADED STUD 2 |
| SWITCH CURRENT RATING AND TYPE IN AMPS | AC 5.0 AND DC 1.0 |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 1 |
| SWITCH TERMINAL TYPE | TAB W/SCREW |
| BODY STYLE | |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| POLE QUANTITY | 1 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 0.170 AND MAXIMUM AT 200 PCT 0.500 |
MOE rules
- MOE rule
- ZH01
- MOE CD
- ZH
- Date assigned
- 01-APR-91
- PICA
- ZH
- PICA LOA
- 81
- Auth collab
- ZH
Freight
- ACTY CD
- XX
Related items
Standardization
- Item standardization code
- E
- Orig stdzn dec
- TX
- Dt stdzn dec
- 21-JAN-2026
- NIIN status code
- 0
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 5925 | 5925-00-556-7400 | 5 | 01-JUL-2026 | A |
| 5925 | 5925-00-583-6440 | 5 | 02-JUL-2026 | A |
Request a quote